Specification support

Toray — Put the technical question in context

Write the reinforcement as a physical object before the nickname: carbon tow, woven or stitched cloth, or a prepreg textile. A search phrase such as toray t700 carbon fiber or toray t800 carbon fiber can sit on the opening line as the family you have in mind. The lines under it should say what was measured, on which specimen, and which choice is still open, such as weave versus tow size or dry infusion versus a resin-filmed ply.

Method
Name the test, or say the method is still unknown
Specimen
Describe tow, dry cloth, prepreg, or a cured coupon

Before you send

Unbranded carbon reinforcement swatches prepared for a written enquiry

A complete note separates the target from any number you already hold. If areal weight was taken on dry cloth, say so, and keep GSM in g/m². If a stiffness figure came from an impregnated strand, do not paste it into a fabric row. Usable width belongs to cloth, in cm, and should say whether selvedge was excluded. Linear density belongs to tow or yarn and should keep dtex or denier visible; a 3K label means 3,000 filaments and is not a yarn count. Fiber composition, when you have it, should sum to 100 percent by mass. Name weave construction and whether warp and weft match. Batch traceability and roll inspection are questions, not files stored with this form. Tensile strength, tear strength, and seam slippage need their own method names. Hydrostatic head, air permeability, coating add-on, and lamination stay out unless that layer is present. ISO 3801 is a cloth-mass method to ask about, not a result from this form. If the choice is dry cloth versus prepreg, or a stock reference versus custom development, say which side the question is on. Quantity and destination describe the commercial frame and should not be written as if they confirmed stock.

If several constructions are still plausible, list them in the order you would trial them and name the single check that would eliminate one, for example a drape trial on the tool or a coupon method you already use. That keeps the message shorter than a full laminate specification and still gives the reader a decision to answer.

Telephone, postal address, and opening hours are not published here. The form below is the route for the reinforcement question. If a certificate or a supplier report is part of the issue, name the holder, the construction it covers, and the date, and leave unsupported claims out of the message. Dimensional stability, colorfastness, and pilling stay off the note unless the surface specification asks for them.

Material inquiry